2.5 Ton Goodman Split Air Conditioner 16 SEER, Single Stage – GSX16S301

Call for Price

Description

Product Specifications

Installation Type Ducted
Communication Feature No
DOE Regional Compliance North;Southeast
Serialized Flag Yes
Item Stocking Unit of Measure (UOM) EA
Pallet Qty 2
Country of Origin USA
US HTS Code 8415.90.8065
Product Description – (PIM) 16 SEER, Air Conditioner, 2-1/2 Ton
AHRI Reference Number 201785791
Cooling Capacity – (Nominal) 29000 Btu/H
EER (HSVTC) 12.2
ENERGY STAR® Certified No
SEER (HSVTC) 14.5
Cooling Operation Range – (Std. Max) 125 °F
Cooling Operation Range – (Std. Min) 55 °F
Rated Cooling Condition – (Ambient DB) 95 °F
Rated Cooling Condition – (Ambient WB) 75 °F
Rated Cooling Condition – (Room DB) 80 °F
Rated Cooling Condition – (Room WB) 67 °F
Subcooling Temp at Service Valve 7-9 °F
Superheat Temp at Service Valve 7-9 °F
Compressor LRA 64 A
Compressor RLA 12.8 A
Control Voltage Conduit Size 1/2 in;3/4 in
Current Type AC
Max Overcurrent Protection 25 A
Max Voltage 253 V
Min. Circuit Amps 17.0 A
Min. Voltage 197 V
Outdoor Fan FLA 0.95 A
Outdoor Fan LRA 2.0 A
Power Frequency 60 Hz
Power Phase 1 Ph
Power Supply Conduit Size 1/2 in;3/4 in
Power Voltage 208/230 V
Air Flow Rate (High) – Cooling 1000 ft³/min
ANSI Certifed Yes
Compressor Sound Blanket No
Compressor Stages Single Stage
Compressor Type Scroll
Condenser Fan Blade Count 3
Condenser Fan Diameter 22 in
Condenser Fan RPM 834 r/min
Dimensions – (Unit Depth) 29-1/4 in
Dimensions – (Unit Height) 36-1/4 in
Dimensions – (Unit Width) 29-1/4 in
Energy Source Electric
ETL Listed Yes
Expansion Device TXV
Indoor Orifice Size .065 in
Motor Speed Type Single Speed PSC
Sound Pressure (High) – Cooling 74 dBA
Sound Pressure (Low) – Cooling N/A dBA
System High Pressure 450 lb/in²
System Low Pressure 240 lb/in²
Weight – (Unit) 149 lb
Condenser Fan Horsepower 1/6 metric hp
Cooling Capacity – (Max) 29400 Btu/H
Cooling Capacity – (Min) 27000 Btu/H
Cooling Capacity – (Rated) 29000 Btu/H
Cooling Capacity – (Sensible) 22000 Btu/H
Cooling Input Power 2.2 kW
Sensible Heat Ratio – (S/T) 0.76
Tonnage 2.5
Additional Refrigerant Charge – (oz/ft) 0.6
Factory Std. Refrigerant Charge 84 oz
Indoor TXV Kit TXV-30
Long Line Set Length – (Equivalent) 250 ft
Pipe Size Gas 5/8 in
Pipe Size Liquid 3/8 in
Refrigerant Pre-Charged Line Length 15 ft
Refrigerant Type R-410A
Standard Line Set Length – (Max) 80 ft
Standard Line Set Length – (Vertical) 50 ft
Valve Connection Type Sweat
Valve Size Liquid (O.D.) 3/8 in
Valve Size Suction (O.D.) 7/8 in
Vertical Length – (OD Above ID) 200 ft
Vertical Length – (OD Below ID) 80 ft
Proposition 65 Label Yes
Dimensions – (Case Depth) 30.50 in
Dimensions – (Case Height) 40.50 in
Dimensions – (Case Width) 30.00 in
Weight – (Case) 169.000 lb
Shipping & Delivery
RockRuth HVAC E-Commerce
Shop
0 Wishlist
0 items Cart
My account