2 Ton Goodman Split Air Conditioner 16 SEER, Two Stage – GSXC160241

Call for Price

Due to the DOE requirements and government regulations regarding equipment phase-outs, we are currently facing certain challenges. We kindly request you to consider checking out the new model GSXC702410 we have available, which shares the same details as the old model GSXC160241. This updated model aligns with the necessary regulations and offers comparable functionality to meet your requirements.

New Model Link:-https://rockruthhvac.shop/product/goodman-2-ton-17-2-seer2-air-handler-heat-pump/

 

Description

 

Product Specifications

Installation Type Ducted
Communication Feature Yes
Communication Feature Type ComfortBridge Technology compatible
DOE Regional Compliance North;Southeast;Southwest
Serialized Flag Yes
Item Stocking Unit of Measure (UOM) EA
Pallet Qty 2
Country of Origin USA
US HTS Code 8415.90.8065
Product Description – (PIM)
16 SEER, Air Conditioner, 2 Ton, Two Stage
AHRI Reference Number 201511904
Cooling Capacity – (Nominal) 23400 Btu/H
EER (HSVTC) 12.2
ENERGY STAR® Certified Yes
SEER (HSVTC) 14
Cooling Operation Range – (Std. Max) 125 °F
Cooling Operation Range – (Std. Min) 55 °F
Rated Cooling Condition – (Ambient DB) 95 °F
Rated Cooling Condition – (Ambient WB) 75 °F
Rated Cooling Condition – (Room DB) 80 °F
Rated Cooling Condition – (Room WB) 67 °F
Subcooling Temp at Service Valve 6 °F
Superheat Temp at Service Valve 8 °F
Compressor LRA 62.9 A
Compressor RLA 10.0 A
Control Voltage Conduit Size 1/2 in;3/4 in
Current Type AC
Max Overcurrent Protection 20 A
Max Voltage 253 V
Min. Circuit Amps 13.6 A
Min. Voltage 197 V
Outdoor Fan FLA 1.1 A
Power Frequency 60 Hz
Power Phase 1 Ph
Power Supply Conduit Size 1/2 in;3/4 in
Power Voltage 208/230 V
Air Flow Rate (High) – Cooling 800 ft³/min
Air Flow Rate (Low) – Cooling 600 ft³/min
Compressor Sound Blanket Yes
Compressor Stages Two Stage
Compressor Type Scroll
Condenser Fan Blade Count 3
Condenser Fan Diameter 26 in
Condenser Fan RPM 845 r/min
Dimensions – (Unit Depth) 29-1/4 in
Dimensions – (Unit Height) 32-1/2 in
Dimensions – (Unit Width) 29-1/4 in
Energy Source Electric
ETL Listed Yes
Expansion Device TXV
Indoor Orifice Size N/A in
Motor Speed Type Two-Speed PSC
Sound Pressure (High) – Cooling 71 dBA
Sound Pressure (Low) – Cooling 68 dBA
Weight – (Unit) 197 lb
Condenser Fan Horsepower 1/6 metric hp
Cooling Capacity – (Rated) 23400 Btu/H
Cooling Capacity – (Sensible) 18200 Btu/H
Cooling Input Power 1.92 kW
Sensible Heat Ratio – (S/T) 0.732
Tonnage 2
Additional Refrigerant Charge – (oz/ft) 0.6
Factory Std. Refrigerant Charge 92 oz
Indoor TXV Kit TX2N4A
Long Line Set Length – (Equivalent) 150 ft
Pipe Size Gas 3/4 in
Pipe Size Liquid 3/8 in
Refrigerant Pre-Charged Line Length 15 ft
Refrigerant Type R-410A
Standard Line Set Length – (Max) 80 ft
Standard Line Set Length – (Vertical) 25 ft
Valve Connection Type Sweat
Valve Size Liquid (O.D.) 3/8 in
Valve Size Suction (O.D.) 3/4 in
Vertical Length – (OD Above ID) 25 ft
Vertical Length – (OD Below ID) 80 ft
Proposition 65 Label Yes
Dimensions – (Case Depth) 30.50 in
Dimensions – (Case Height) 34.50 in
Dimensions – (Case Width) 30.00 in
Weight – (Case) 168.000 lb
Shipping & Delivery
RockRuth HVAC E-Commerce
Shop
0 Wishlist
0 items Cart
My account