Due to the DOE requirements and government regulations regarding equipment phase-outs, we are currently facing certain challenges. We kindly request you to consider checking out the new model GSXC706010 we have available, which shares the same details as the old model GSXC160601. This updated model aligns with the necessary regulations and offers comparable functionality to meet your requirements.

New Model Link:-https://rockruthhvac.shop/product/goodman-split-air-conditioner-17-2-seer2-2/

 

SKU GSXC160601 Categories , , Brand:
Description

 

Product Specifications

Installation Type Ducted
Communication Feature Yes
Communication Feature Type ComfortBridge Technology compatible
DOE Regional Compliance North;Southeast;Southwest
Serialized Flag Yes
Item Stocking Unit of Measure (UOM) EA
Pallet Qty 1
Country of Origin USA
US HTS Code 8415.90.8065
Product Description – (PIM)
16 SEER, Air Conditioner, 5 Ton, Two Stage
AHRI Reference Number 201522606
Cooling Capacity – (Nominal) 56500 Btu/H
EER (HSVTC) 12
ENERGY STAR® Certified Yes
SEER (HSVTC) 15
Cooling Operation Range – (Std. Max) 125 °F
Cooling Operation Range – (Std. Min) 55 °F
Rated Cooling Condition – (Ambient DB) 95 °F
Rated Cooling Condition – (Ambient WB) 75 °F
Rated Cooling Condition – (Room DB) 80 °F
Rated Cooling Condition – (Room WB) 67 °F
Subcooling Temp at Service Valve 6 °F
Superheat Temp at Service Valve 8 °F
Compressor LRA 147.2 A
Compressor RLA 22.9 A
Control Voltage Conduit Size 1/2 in;3/4 in
Current Type AC
Max Overcurrent Protection 50 A
Max Voltage 253 V
Min. Circuit Amps 31.4 A
Min. Voltage 197 V
Outdoor Fan FLA 2.8 A
Power Frequency 60 Hz
Power Phase 1 Ph
Power Supply Conduit Size 1/2 in;3/4 in
Power Voltage 208/230 V
Air Flow Rate (High) – Cooling 1480 ft³/min
Air Flow Rate (Low) – Cooling 1110 ft³/min
Compressor Sound Blanket Yes
Compressor Stages Two Stage
Compressor Type Scroll
Condenser Fan Blade Count 3
Condenser Fan Diameter 26 in
Condenser Fan RPM 1000 r/min
Dimensions – (Unit Depth) 35-3/4 in
Dimensions – (Unit Height) 42-1/4 in
Dimensions – (Unit Width) 35-3/4 in
Energy Source Electric
ETL Listed Yes
Expansion Device TXV
Indoor Orifice Size N/A in
Motor Speed Type Multi Speed ECM
Sound Pressure (High) – Cooling 74 dBA
Sound Pressure (Low) – Cooling 70 dBA
Weight – (Unit) 326 lb
Condenser Fan Horsepower 1/3 metric hp
Cooling Capacity – (Rated) 56000 Btu/H
Cooling Capacity – (Sensible) 39300 Btu/H
Cooling Input Power 4.66 kW
Sensible Heat Ratio – (S/T) 0.743
Tonnage 5
Additional Refrigerant Charge – (oz/ft) 0.6
Factory Std. Refrigerant Charge 191 oz
Indoor TXV Kit TX3N4
Long Line Set Length – (Equivalent) 150 ft
Pipe Size Gas 1-1/8 in
Pipe Size Liquid 3/8 in
Refrigerant Pre-Charged Line Length 15 ft
Refrigerant Type R-410A
Standard Line Set Length – (Max) 80 ft
Standard Line Set Length – (Vertical) 25 ft
Valve Connection Type Sweat
Valve Size Liquid (O.D.) 3/8 in
Valve Size Suction (O.D.) 7/8 in
Vertical Length – (OD Above ID) 25 ft
Vertical Length – (OD Below ID) 80 ft
Proposition 65 Label Yes
Dimensions – (Case Depth) 37.00 in
Dimensions – (Case Height) 44.00 in
Dimensions – (Case Width) 37.00 in
Weight – (Case) 307.000 lb