2 Ton Goodman Split Heat Pump 18 SEER, Two Stage – GSZC180241

Call for Price

Due to the DOE requirements and government regulations regarding equipment phase-outs, we are currently facing certain challenges. We kindly request you to consider checking out the new model GSZC702410 we have available, which shares the same details as the old model GSZC180241. This updated model aligns with the necessary regulations and offers comparable functionality to meet your requirements.

New Model Link:- https://rockruthhvac.shop/product/2-ton-goodman-sp…seer2-gszc702410/

Description

 

Product Specifications

Installation Type Ducted
Communication Feature Yes
Communication Feature Type ComfortBridge Technology compatible
DOE Regional Compliance Southwest;Southeast;North
Item Stocking Unit of Measure (UOM) EA
Pallet Qty 1
Country of Origin USA
US HTS Code 8415.90.8065
Product Description – (PIM) 18 seer hp, 2 ton
AHRI Reference Number 201690719
Cooling Capacity – (Nominal) 23800 Btu/H
COP17 (HSVTC) 2.54
COP17 Ducted 2.54
COP47 (HSVTC) 4.22
COP47 Ducted 4.26
EER (HSVTC) 14
EER Ducted 14
ENERGY STAR® Certified Yes
Heating Capacity – (Nominal) 23000 Btu/H
HSPF (HSVTC) 10
HSPF Ducted 10
SEER (HSVTC) 18
SEER Ducted 18
Compressor High Stage Temp Range 8-10 °F
Compressor Low Stage Temp Range 5-7 °F
Cooling Operation Range – (Std. Max) 125 °F
Cooling Operation Range – (Std. Min) 55 °F
Heating Operation Range – (Std.Max) 70 °F
Heating Operation Range – (Std.Min) -20 °F
Rated Cooling Condition – (Ambient DB) 95 °F
Rated Cooling Condition – (Ambient WB) 75 °F
Rated Cooling Condition – (Room DB) 80 °F
Rated Cooling Condition – (Room WB) 67 °F
Rated Heating Condition – (Ambient DB) 47 °F
Rated Heating Condition – (Ambient WB) 43 °F
Rated Heating Condition – (Room DB) 70 °F
Rated Heating Condition – (Room WB) 60 °F
Subcooling Temp at Service Valve 5-7 °F
Superheat Temp at Service Valve 7-9 °F
Compressor LRA 62.9 A
Compressor RLA 10.0 A
Control Voltage Conduit Size 1/2 in;3/4 in
Current Type AC
Max Overcurrent Protection 25 A
Max Voltage 253 V
Min. Circuit Amps 15.3 A
Min. Voltage 197 V
Outdoor Fan FLA 2.8 A
Power Frequency 60 Hz
Power Phase 1 Ph
Power Supply Conduit Size 1/2 in;3/4 in
Power Voltage 208/230 V
Air Flow Rate (High) – Cooling 855 ft³/min ft³/min
Air Flow Rate (High) – Heating 855 ft³/min
Air Flow Rate (Low) – Cooling 460 ft³/min
Air Flow Rate (Low) – Heating 460 ft³/min
Compressor Sound Blanket Yes
Compressor Stages Two Stage
Compressor Type Scroll
Condenser Fan Blade Count 3
Condenser Fan Diameter 26 in
Condenser Fan RPM 850 r/min
Dimensions – (Unit Depth) 35-3/4 in
Dimensions – (Unit Height) 40 in
Dimensions – (Unit Width) 35-3/4 in
Energy Source Electric
ETL Listed Yes
Expansion Device TXV
Heat Exchanger Type Air Cooled
Indoor Orifice Size N/A in
Sound Pressure (High) – Cooling 68 dBA
Sound Pressure (High) – Heating 69 dBA
Sound Pressure (Low) – Cooling 67 dBA
System High Pressure 450 lb/in²
System Low Pressure 240 lb/in²
Weight – (Unit) 230 lb
Condenser Fan Horsepower 1/3 metric hp
Cooling Capacity – (Rated) 23800 Btu/H
Cooling Capacity – (Sensible) 19400 Btu/H
Tonnage 2
Additional Refrigerant Charge – (oz/ft) 0.6
Factory Std. Refrigerant Charge 187 oz
Indoor TXV Kit TX2N4A
Long Line Set Length – (Equivalent) 150 ft
Pipe Size Gas 3/4 in
Pipe Size Liquid 3/8 in
Refrigerant Pre-Charged Line Length 15 ft
Refrigerant Type R-410A
Standard Line Set Length – (Max) 80 ft
Standard Line Set Length – (Vertical) 25 ft
Valve Connection Type Sweat
Valve Size Liquid (O.D.) 3/8 in
Valve Size Suction (O.D.) 3/4 in
Vertical Length – (OD Above ID) 25 ft
Vertical Length – (OD Below ID) 80 ft
Proposition 65 Label Yes
Dimensions – (Case Depth) 37.00 in
Dimensions – (Case Height) 44.00 in
Dimensions – (Case Width) 37.00 in
Weight – (Case) 250.000 lb