2 Ton Goodman Split Heat Pump 16 SEER, Two Stage – GSZC160241

Call for Price

Due to the DOE requirements and government regulations regarding equipment phase-outs, we are currently facing certain challenges. We kindly request you to consider checking out the new model GSZC702410 we have available, which shares the same details as the old model GSZC160241. This updated model aligns with the necessary regulations and offers comparable functionality to meet your requirements.

New Model Link: https://rockruthhvac.shop/product/2-ton-goodman-sp…seer2-gszc702410/

 

Description

 

Product Specifications

Installation Type Ducted
Communication Feature Yes
Communication Feature Type ComfortBridge Technology compatible
DOE Regional Compliance North;Southeast;Southwest
Item Stocking Unit of Measure (UOM) EA
Pallet Qty 1
Country of Origin USA
US HTS Code 8415.90.8065
Product Description – (PIM) 16 seer hp, 2 ton
AHRI Reference Number 202149334
Cooling Capacity – (Nominal) 23600 Btu/H
COP17 (HSVTC) 2.6
COP17 Ducted 2.6
COP47 (HSVTC) 4.02
COP47 Ducted 4
EER (HSVTC) 13
EER Ducted 13
ENERGY STAR® Certified Yes
Heating Capacity – (Nominal) 22200 Btu/H
HSPF (HSVTC) 9
HSPF Ducted 9
SEER (HSVTC) 16
SEER Ducted 16
Cooling Operation Range – (Std. Max) 115 °F
Cooling Operation Range – (Std. Min) 55 °F
Heating Operation Range – (Std.Max) 70 °F
Heating Operation Range – (Std.Min) -20 °F
Rated Cooling Condition – (Ambient DB) 95 °F
Rated Cooling Condition – (Ambient WB) 75 °F
Rated Cooling Condition – (Room DB) 80 °F
Rated Cooling Condition – (Room WB) 67 °F
Rated Heating Condition – (Ambient DB) 47 °F
Rated Heating Condition – (Ambient WB) 43 °F
Rated Heating Condition – (Room DB) 70 °F
Rated Heating Condition – (Room WB) 60 °F
Subcooling Temp at Service Valve 6 °F
Superheat Temp at Service Valve 8 °F
Compressor LRA 62.9 A
Compressor RLA 10.0 A
Control Voltage Conduit Size 1/2 in;3/4 in
Current Type AC
Max Overcurrent Protection 20 A
Max Voltage 253 V
Min. Circuit Amps 13.5 A
Min. Voltage 197 V
Outdoor Fan FLA 1 A
Power Frequency 60 Hz
Power Phase 1 Ph
Power Supply Conduit Size 1/2 in;3/4 in
Power Voltage 208/230 V
Rated Load Amps 10 A
Air Flow Rate (High) – Cooling 860 ft³/min
Air Flow Rate (High) – Heating 860 ft³/min
Air Flow Rate (Low) – Cooling 500 ft³/min
Air Flow Rate (Low) – Heating 500 ft³/min
Compressor Sound Blanket Yes
Compressor Stages Two Stage
Compressor Type Scroll
Condenser Fan Blade Count 3
Condenser Fan Diameter 26 in
Condenser Fan RPM 830 r/min
Dimensions – (Unit Depth) 35-3/4 in
Dimensions – (Unit Height) 36-1/4 in
Dimensions – (Unit Width) 35-3/4 in
Energy Source Electric
ETL Listed Yes
Expansion Device TXV
Heat Exchanger Type Air Cooled
Indoor Orifice Size N/A in
Sound Pressure (High) – Cooling 73 dBA
Sound Pressure (High) – Heating 74 dBA
Sound Pressure (Low) – Cooling 71 dBA
System High Pressure 450 lb/in²
System Low Pressure 240 lb/in²
Weight – (Unit) 215 lb
Condenser Fan Horsepower 1/5 metric hp
Cooling Capacity – (Rated) 23600 Btu/H
Cooling Capacity – (Sensible) 19000 Btu/H
Heating Capacity – (Max) 22500 Btu/H
Heating Capacity – (Min) 13600 Btu/H
Sensible Heat Ratio – (S/T) 0.81
Tonnage 2
Additional Refrigerant Charge – (oz/ft) 0.6
Factory Std. Refrigerant Charge 176 oz
Indoor TXV Kit TX2N4A
Long Line Set Length – (Equivalent) 150 ft
Pipe Size Gas 3/4 in
Pipe Size Liquid 3/8 in
Refrigerant Pre-Charged Line Length 15 ft
Refrigerant Type R-410A
Standard Line Set Length – (Max) 80 ft
Standard Line Set Length – (Vertical) 50 ft
Valve Connection Type Sweat
Valve Size Liquid (O.D.) 3/8 in
Valve Size Suction (O.D.) 3/4 in
Vertical Length – (OD Above ID) 25 ft
Vertical Length – (OD Below ID) 80 ft
Proposition 65 Label Yes
Dimensions – (Case Depth) 37.00 in
Dimensions – (Case Height) 38.50 in
Dimensions – (Case Width) 37.00 in
Weight – (Case) 235.000 lb